SPARTAN™ Hose | Parker SW593 Series

SPARTAN - UHMWPE Chemical Hose - Series SW593


Series SW593 is a lightweight, high-pressure, high-temperature suction and discharge hose designed to handle approximately 98% of commonly used acids, chemicals, and solvents. The ultra-high molecular weight polyethylene (UHMWPE) tube will not leach into and contaminate the product being conveyed. The hose construction incorporates a dual wire helix that provides full suction capability, kink resistance, flexibility for ease of handling, and a path to conduct a static electrical charge to ground. The cover is resistant to abrasion, mild chemicals, and ozone.

Parker SPARTAN Hose Sizes & Specifications 

  • Tube: Translucent ultra-high molecular weight polyethylene (UHMWPE)Reinforcement: Multiple textile plies with dual wire helix
  • Cover: Green EPDM; wrapped finish
  • Temp. Range: -40°F to +250°F (-40°C to +121°C)
  • Brand Method: Green text on yellow stripe
  • Brand Example: PARKER SERIES SW593 SPARTAN™ UHMWPE CHEMICAL SUCTION HOSE 200 PSI WP
  • Design Factor: 4:1
  • Industry Standards: None applicable
  • Applications: • Acids, chemicals, solvents• In-plant tank transfer• Delivery, transport
  • Vacuum: Full
  • Packaging: Coils

Part Number

ID

Reinf
Plies

OD

Approx Wt

Min Bend Rad

Max Rec WP

Perm
Cplg Rec

in

mm

in

mm

lbs/ft

kg/ft

in

mm

psi

bar

SW593-1000

1

25.4

2

1.375

34.9

0.41

0.19

6.0

152.4

200

13.8

*

SW593-1500

1-1/2

38.1

2

1.875

47.6

0.63

0.29

9.0

228.6

200

13.8

*

SW593-2000

2

50.8

2

2.438

61.9

1.01

0.46

12.0

304.8

200

13.8

*

SW593-3000

3

76.2

2

3.440

87.3

1.63

0.74

18.0

457.2

200

13.8

*

 


WARNINGS!
„ It is the responsibility of the user to determine if the hose is suitable for the application. Most chemical resistance guides are based on temperatures of 70°F (21°C). Elevated temperatures can change the chemical resistance ratings. Many chemicals will become more aggressive as temperatures increase, reducing the ability of hose compounds to withstand them. Contact Parker for chemical compatibility data at elevated temperatures. If no data exists, users are required to perform compatibility testing at the desired temperature.

„ At operating temperatures of 125°F and above, only permanently attached couplings should be installed. At any operating temperature, couplings attached with bands or clamps may reduce the working pressure of the hose assembly to less than the maximum rated working pressure of the hose. Refer to the NAHAD Industrial Hose Assembly Guidelines.

„ Do not use with internally expanded couplings. Refer to chemical hoses that incorporate a MXLPE tube.

 

Follow Me

Orders & Quotes

PLACE ORDER
 REQUEST QUOTE
 ASK QUESTION