Stainless Steel Regulators | Parker PR10 Standard Knob Series

 SS-FRLs-PR10-Standard-Regulator

FEATURES

  • 1/2" ports (NPT, BSPP)
  • Large diaphragm to valve area ratio for precise regulation and high flow capacity
  • Meets NACE specifications MR-01-75/ISO 15156
  • Low temperature version available
  • Stainless steel construction handles most corrosive environments

SYMBOLS

Regulator-Symbol-1

Back to Stainless Steel FRLs Main Page


Part Numbers



Part Number*  Description

Port Size

Flow
(scfm)

Max. Bar (psig)

Height (E)

mm (in)

Width (A)

mm (in)

PR10-04CSS

NPT port, 0-125 psig, relieving

 1/2" 80 20.7 (300) 126 (4.97) 60 (2.34)
PR10-04CKSS

NPT port, 0-125 psig, non-relieving

1/2" 80 20.7 (300) 126 (4.97) 60 (2.34)
PR10G04CSS BSPP port, 0-125 psig, relieving 1/2" 80 20.7 (300) 126 (4.97) 60 (2.34)
PR10G04CKSS BSPP port, 0-125 psig, non-relieving 1/2" 80 20.7 (300) 126 (4.97) 60 (2.34)
* For other pressure ranges, replace "C" with "B" for 0-60 PSIG, or "D" for 0-250 PSIG.

SS-FRLs-PR10-Standard-Regulator-Dimensions


Service Kits and Accessories

Part Number Description
R10Y57-SS Panel mount bracket - stainless
R01X51-SS

Panel mount nut - stainless

R01X51-P Panel mount nut - plastic
616A28-SS Pipe nipple - 1/2"
RKR10YSS Service kit - relieving
RKR10KYSS Service kit - non-relieving
K4520N14160SS 160 PSIG, 2" face gauge

Technical Specifications

Flow Capacity:

80 SCFM

Operating Temperature*: 0°F to 150°F
Max. Pressure Rating: 20.7 bar (300 psig)
Port Size: 1/2" (BSPP, NPT)
Weight: 1.79 lb (0.81 kg)
* Air must be dry enough to avoid ice formation at temperatures below 32°F

Warning Triangle WARNING: These products can expose you to chemicals including lead and/or DEHP and/or carbon black, which are known to the State of California to cause cancer or birth defects or other reproductive harm.  For more information go to www.P65Warnings.ca.gov