POLY-CHEM® Hose | Parker 7274 Series

POLY-CHEM - XLPE Corrugated Chemical Hose - Series 7274


Series 7274 is a flexible suction and discharge hose designed to handle many commonly used acids, chemicals and solvents. The cross-linked polyethylene (XLPE) tube will not leach into and contaminate the product being conveyed. The corrugated hose construction incorporates a wire helix that provides full suction capability, flexibility, kink resistance and a path to conduct a static electrical charge to ground. The cover is resistant to abrasion, mild chemicals and ozone. Series 7274 is available in 200-foot continuous lengths.

Parker POLY-CHEM Hose Sizes & Specifications 

  • Tube: Translucent cross-linked polyethylene (XLPE)
  • Reinforcement: Multiple textile plies with dual wire helix
  • Cover: Green EPDM; corrugated wrapped finish
  • Temp. Range: -20°F to +160°F (-29°C to +71°C)
  • Brand Method: Green text on yellow stripe
  • Brand Example: PARKER SERIES 7274 CORRUGATED POLY-CHEM® 200 PSI MAX WPMADE IN USA (LOT#)
  • Design Factor: 4:1
  • Industry Standards: None applicable
  • Applications: • Acids, chemicals, solvents• In-plant tank transfer• Delivery, transport
  • Vacuum: Full
  • Compare to: Boston Panther Chemical Transfer; Veyance Blue Flexwing
  • Packaging: Coils

Part Number

ID

Reinf Plies

OD

Approx Wt

Min Bend Rad

Max Rec WP

Perm Cplg Rec

in

mm

in

mm

lbs/ft

kg/ft

in

mm

psi

bar

7274-1002

1

25.4

2

1.475

37.5

0.55

0.25

3.0

76.2

200

13.8

43

7274-1252

1-1/4

31.8

2

1.710

43.4

0.63

0.29

4.0

101.6

200

13.8

43

7274-1502

1-1/2

38.0

2

2.000

50.8

0.77

0.35

5.0

127.0

200

13.8

43

7274-2002

2

50.8

2

2.519

65.2

1.14

0.52

6.0

152.4

200

13.8

43, RE, RST, TM, WC

7274-2502

2-1/2

63.5

4

3.086

78.4

1.58

0.72

7.0

177.8

200

13.8

*

7274-3002

3

76.2

4

3.580

90.9

1.91

0.87

7.0

177.8

200

13.8

RE, RST, TM

7274-4002

4

101.6

4

4.710

119.6

2.85

1.29

8.0

203.2

200

13.8

*

 


WARNINGS!
„ It is the responsibility of the user to determine if the hose is suitable for the application. Most chemical resistance guides are based on temperatures of 70°F (21°C). Elevated temperatures can change the chemical resistance ratings. Many chemicals will become more aggressive as temperatures increase, reducing the ability of hose compounds to withstand them. Contact Parker for chemical compatibility data at elevated temperatures. If no data exists, users are required to perform compatibility testing at the desired temperature.
„ At operating temperatures of 125°F and above, only permanently attached couplings should be installed. At any operating temperature, couplings attached with bands or clamps may reduce the working pressure of the hose assembly to less than the maximum rated working pressure of the hose. Refer to the NAHAD Industrial Hose Assembly Guidelines.
„ Do not use with internally expanded couplings. Refer to chemical hoses that incorporate a MXLPE tube.

 