TITANFLEX FEP Chemical Hose | Parker SW574 Series
TITANFLEX FEP Chemical Hose - FDA, USDA, 3-A - Series SW574
Series SW574 is a flexible, lightweight, premium quality suction and discharge hose designed for use in high temperature, high-pressure chemical, and purity applications. The fluorinated ethylene propylene (FEP) tube is compatible with 99.5% of commonly used chemicals and solvents, as well as food, pharmaceutical, and sanitary materials. The tube also has an elevated temperature rating of 300°F (149°C), will not leach into and contaminate the product being conveyed, and meets FDA, USDA, and 3-A requirements. The special construction incorporates a dual wire helix that provides full suction capability, superior force-to-bend and kink resistance, and a path to conduct a static electrical charge to ground. The EPDM cover is resistant to abrasion, mild chemicals, and ozone.
Parker TITANFLEX FEP Chemical Hose Sizes & Specifications
|
Part Number |
ID |
Reinf |
OD |
Approx Wt |
Min Bend Rad |
Max Rec WP |
Perm |
|||||
in |
mm |
in |
mm |
lbs/ft |
kg/ft |
in |
mm |
psi |
bar |
|||
SW574-750 |
3/4 |
19.1 |
2 |
1.281 |
32.5 |
0.48 |
0.22 |
2.0 |
50.8 |
400 |
27.6 |
* |
SW574-1000 |
1 |
25.4 |
2 |
1.469 |
37.3 |
0.52 |
0.24 |
2.5 |
63.5 |
400 |
27.6 |
* |
SW574-1500 |
1-1/2 |
38.1 |
2 |
2.031 |
51.6 |
0.81 |
0.37 |
4.0 |
101.6 |
300 |
20.7 |
* |
SW574-2000 |
2 |
50.8 |
2 |
2.531 |
64.3 |
1.11 |
0.50 |
6.5 |
165.1 |
300 |
20.7 |
* |
SW574-3000 |
3 |
76.2 |
2 |
3.688 |
93.7 |
2.17 |
0.98 |
12.0 |
304.8 |
200 |
13.8 |
* |
SW574-4000 |
4 |
101.6 |
2 |
4.688 |
119.1 |
3.03 |
1.37 |
18.0 |
457.2 |
200 |
13.8 |
* |
WARNINGS!
It is the responsibility of the user to determine if the hose is suitable for the application. Most chemical resistance guides are based on temperatures of 70°F (21°C). Elevated temperatures can change the chemical resistance ratings. Many chemicals will become more aggressive as temperatures increase, reducing the ability of hose compounds to withstand them. Contact Parker for chemical compatibility data at elevated temperatures. If no data exists, users are required to perform compatibility testing at the desired temperature.
At operating temperatures of 125°F and above, only permanently attached couplings should be installed. At any operating temperature, couplings attached with bands or clamps may reduce the working pressure of the hose assembly to less than the maximum rated working pressure of the hose. Refer to the NAHAD Industrial Hose Assembly Guidelines.