FEP Tubing | Parker Series 103 - Heavy Wall, Fractional Sizes

FEP tubing, 103-203 series

Return to Plastic Tubing Selection Page

FEATURES:

  • Virgin fluorinated ethylene propylene resin
  • Translucent
  • Chemically inert
  • Low coefficient of friction
  • Long continuous lengths
  • Self extinguishing
  • Non-wetting
  • Weldable

CERTIFICATIONS

  • ASTM D3307-10, ASTM D2116-07
  • VW-1, UL-83 (natural)
  • FDA Compliant
  • USP Class VI Compliant

Sizes and Specifications

Colors: Natural, Translucent

(Other colors available as custom run - see color code table below)

 tubing-parker-101-201-series-colors.png

Part #
Order Size Nominal O.D. (in) Nominal I.D. (in) Reference Wall Working Pressure (psi, at 73°F/23°C) Burst Pressure (psi, at 73°F/23°C) Min. Bend Radius (in)

Vac. Rating

103-0188062 3/16 0.188 0.064 .062 630 2520 0.250 28
103-0250040 1/4 0.250 0.170 .040 280 1120 1.250 28
103-0250047 1/4 0.250 0.156 .047 340 1360 0.750 28
103-0250062 1/4 0.250 0.125 .062 470 1880 0.750 28
103-0312062 5/16 0.312 0.188 .062 360 1440 1.375 28
103-0375062 3/8 0.375 0.250 .062 290 1160 1.500 28
103-0438062 7/16 0.438 0.312 .062 250 1000 2.625 28
103-0500062 1/2 0.500 0.375 .062 210 840 2.125 28
103-0625062 5/8 0.625 0.500 .062 160 640 3.000 28
103-0750062 3/4 0.750 0.625 .062 130 520 6.000 28
103-1000062 1 1.000 0.875 .062 90 360 8.000 28


Notes

  • Working Temperature: -100°F to 400°F (-75°C to 204°C)
  • Working pressure calculated using a Design Factor of 4 at 73°F (23°C)

Use with The Following Parker Fittings

  • Compression
  • Compress-Align
  • TrueSeal

 

How to Order

  • Visit One of Our ParkerStores
  • Click on the quote button below.
 ASK QUESTION!  REQUEST QUOTE

 

 

IMPORTANT!
Hose and hose fittings series must be correctly matched. Using any fittings other than those specifically designated by the hose manufacturer for use with each specific hose can lead to hose assembly failure. Hose assembly failures have lead to damage, injury and death.

California Prop 65 Warning WARNING: These products can expose you to chemicals including lead and/or DEHP and/or carbon black, which are known to the State of California to cause cancer or birth defects or other reproductive harm.  For more information go to www.P65Warnings.ca.gov