CAN Pressure Transducers for Parker SensoControl Meters
![]() |
|
SensoControl CAN Transducers | Part Numbers & Technical Data
PD##-0100-CAN |
PD##-0600-CAN |
PD##-1500-CAN |
PD##-4000-CAN |
PD##-6000-CAN |
|
Color Code | Blue | Green | Yellow | Orange | Red |
Pressure Range (PSI) | -14.5 - 235 | 0 - 870 | 0- 2175 | 0 - 5800 | 0 - 8700(1) |
Temperature Range (°F) | -13 - 221 | -13 - 221 | -13 - 221 | -13 - 221 | -13 - 221 |
Max. Overload Pressure (PSI) | 434 | 1740 | 4350 | 11600 | 17400 |
Response Time (ms) | 1 | 1 | 1 | 1 | 1 |
Excitation Voltage (V DC) | 8 - 40 | 8 - 40 | 8 - 40 | 8 - 40 | 8 - 40 |
Accuracy (Max) | 0.50% FS | 0.50% FS | 0.50% FS | 0.50% FS | 0.50% FS |
"##" in the part number represents: TA = PD Style; PTA = PDP Style; TEMA3 = EMA3 Style (Female)
Excitation Voltage: 8-40 VDC
Electrical Connection: 5 pin, M 12 x 1 connection
Port Connection: 1/2 " BSPP
Housing: Stainless Steel 1.4301
Seal Material: FKM
Ambient Temperature Range: -13 to 185°F
Max. Fluid Temperature: 221°F
Shock Resistence: IEC 6.8-2-29
Vibration Resistence: IEC 6.8-2-6.